Product Overview
Anti-static vinyl flooring It is a specialized flooring material designed to meet strict standards for static control in modern industrial environments. With its ability to prevent the accumulation and generation of static electricity, the product helps protect sensitive electronic components, precision machinery, and ensures the safety and health of workers.
Widely applied in cleanrooms, electronics factories, pharmaceuticals, medical device facilities, and electrostatic protected areas (EPA), anti-static vinyl flooring is not only a protective solution but also helps businesses enhance their manufacturing standards.
Detailed Product Description – Anti-Static Vinyl Flooring

- Product Name ESD Anti-Static Vinyl Flooring
- Product Code: ESD-VNYL-2mm
- Material: Virgin PVC combined with evenly dispersed conductive carbon particles
- Structure: 3 layers (wear-resistant surface layer – central conductive layer – PVC backing layer)
- Standard Thickness: 2mm / 3mm
- Roll size: Width 1.5m × Length 10m/roll or loose tiles 600 × 600mm
- Density: ~2.5kg/m²
- Color: Blue, light gray, moss green, speckled gray (optional depending on space)
- Surface Resistance: 10^6 ~ 10^9 Ω
- Slip Resistance: R9 according to DIN 51130 standard
- Standard: ISO 9001, ISO 14001, ESD S20.20, RoHS
- Heat Resistance: -15°C to +50°C
The product has the ability to conduct residual static charges to the grounding system through a connecting wire, thereby eliminating the risk of unexpected electrostatic discharge (ESD) that could damage components or compromise production safety.
Practical Applications of Anti-Static Vinyl Flooring
Anti-static vinyl flooring is widely used in:
- Anti-static vinyl flooring is widely used in:
- ISO Class 7/8 cleanrooms in the pharmaceutical and medical device industries.
- Research centers and precision electronics laboratories.
- Hospitals, diagnostic and testing equipment operation areas.
- Electrostatic Protected Areas (EPA), workstations, and assembly lines.
- Cosmetics and high-end food production areas – where clean and safe flooring is required.
The product is especially suitable for enterprises in industrial zones in Northern Vietnam such as: Quang Châu Industrial Park, Đình Trám Industrial Park (Bắc Giang), VSIP Bắc Ninh Industrial Park, Đại An Industrial Park (Hải Dương),…
Outstanding Benefits of Using Anti-Static Vinyl Flooring

- Control and eliminate static charges: Protect sensitive equipment and prevent ESD.
- Extends the lifespan of electronic components and measuring equipment.
- Enhances worker safety and reduces accidents caused by electrostatic discharge.
- Fully compliant with international GMP, ISO, and ESD standards.
- Durable surface, easy to clean, and reduces long-term maintenance costs.
- High aesthetics, suitable for various modern factory design styles.
Structure and Technical Design of Anti-Static Vinyl Flooring

The flooring is constructed from multiple layers, each with its own specific function:
- Top surface layer: High wear resistance, slip-resistant, and easy to clean.
- Intermediate conductive layer: Contains carbon fibers or graphite to effectively conduct static electricity.
- PVC backing layer: Good floor adhesion, structural stability, load-bearing capacity, and noise reduction during movement.
In addition, the flooring can withstand light impacts, has good abrasion resistance, and its smooth surface prevents foot fatigue during long periods of movement.
Installation and Effective Usage Guidelines
Installation Procedure for Anti-Static Vinyl Flooring
- Level and clean the concrete base or old flooring.
- Apply specialized conductive adhesive evenly on the surface.
- Lay the vinyl flooring and join the sheets using seam welding or dry adhesive.
- Connect the grounding wire at the designated points (according to the installation drawing).
- Check the resistance after completion using specialized ESD measuring equipment.
Proper Maintenance and Cleaning
- Use a damp mop and non-alkaline, non-corrosive floor cleaning solution.
- Limit exposure to strong chemicals such as acids and industrial solvents.
- Do not drag heavy objects across the floor; use soft wheels when moving equipment.
Precautions During Use
- Do not use outdoors or in areas with excessive humidity (>70%).
- Avoid installation when the temperature is below 15°C or above 35°C.
- Periodically check grounding resistance to ensure ESD effectiveness.
Place to buy – reputable and high-quality address
If you are looking for anti-static vinyl flooring that meets strict standards in industrial production environments, cleanrooms, or electrostatic protected areas (EPA) – then Goma Food Machinery is the reliable choice.
We are committed to providing our customers with Comprehensive solution with genuine products, in-depth technical consulting, clear warranty, and the most competitive pricing in the market.
In addition, to serve customers in Northern Vietnam, customers can directly contact official authorized distribution partner:
AN BINH VINA TRADING & SERVICE CO., LTD
📍 AddressKha Ly Thuong Residential Group, Quang Minh Ward, Viet Yen Town, Bac Giang Province
📞 Hotline: 0866 732 555 (7:30 AM – 10:00 PM)
📧 Email: Email: anbinhvinaKL@gmail.com









Review Conductive Carbon Particle ESD-Safe Vinyl Flooring